Delta-electronics RTU-DNET Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Delta-electronics RTU-DNET. Delta Electronics RTU-DNET User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 41
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
RTU-DNET
DeviceNet Remote I/O Communication
Module
Application Manual
Vista de página 0
1 2 3 4 5 6 ... 40 41

Resumo do Conteúdo

Página 1 - RTU-DNET

RTU-DNET DeviceNet Remote I/O Communication Module Application Manual

Página 2

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 8 3.3 Connecting to DeviceNet Connection Port z The colors on the PINs

Página 3 - Table of Contents

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 9No. Item Unit Explanation 5 Length of input data of special module W

Página 4

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 10 Byte position Data written into special module Data read from speci

Página 5 - 1 Introduction

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 11AttributeID Access rule Name Range Default Explanation 8 Get Status

Página 6

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 12 Attribute ID Access rule Name Range Default Explanation 1Special mod

Página 7 - 2.2 Product Profiles

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 13Attribute ID Access rule Name Range Default Explanation 30 Get/Set St

Página 8

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 14 Attribute ID Access rule Name Range Default Explanation 61 Get/SetOu

Página 9 - 3 Basic Operation

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 15bit Status value Explanation 2 0/1 Reserved 3 0/1 Reserved 4 0/1

Página 10 - 4 How to Configure RTU-DNET

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 16 bit Status value Explanation 14 0/1 Reserved 15 0/1 Reserved 2.

Página 11

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 17Master (byte) RTU-DNET … … z RTU-DNET → DeviceNet master Master (byte

Página 13

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 18 Item Content Software screen DIDO Input Points (X) 16 bits DIDO Out

Página 14

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 19 (2) Double click on RTU-DNET icon, and the “Node Configuration…” dial

Página 15

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 20 (5) Click on “OK”. DeviceNetBuilder will then display the special mo

Página 16

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 21 (8) Click on “OK” in “AIAO Module Configuration” page and return to “

Página 17

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 22 5 How to Construct a DeviceNet Network Using RTU-DNET In this sectio

Página 18

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 23(2) Select “Setup” => “Communication Setting” => “System Channel

Página 19 - 4.4 Example

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 24 (6) Click on “OK”, and DeviceNetBuilder will start to scan the entir

Página 20

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 25 (9) Click on “IO Configure…” button in “Node Configuration" dial

Página 21

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 26 (12) Double click on RTU-DNET icon, and you will then see “RTU Setup

Página 22

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 27Item Function Default IO Module Error Treatment How RTU-DNET will re

Página 23 - DVP-PLC Application Manual

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 1 Warning 3 Please read this instruction carefully before use and follow

Página 24 - DVPDNET DVP28SV

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 28 (3) Confirm all the settings and click on “OK”. Next, download the c

Página 25

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 29(1) DVPDNET-SL → RTU-DNET Register in DVPDNET-SL Devices in extensio

Página 26

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 30 Register in DVPDNET-SL Devices in extension module D6287H High byte

Página 27

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 316 LED Indicator & Trouble-shooting There are five LED indicators

Página 28

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 32 LED status Indication How to correct voltage 2. Acquire diagnosti

Página 29

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 33Common services Implemented for Service code Class Instance Service n

Página 30

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 34 Implemented for Service code Class Instance Service name 0x10 No Yes

Página 31

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 35Common services Implemented for Service code Class Instance Service n

Página 32

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 36 Attribute ID Access rule Name Range Default Explanation offline trea

Página 33 - 6.2 NS LED

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 37Attribute ID Access rule Name Range Default Explanation 1 Special mo

Página 34 - 6.5 RUN LED

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 2 4.3 DeviceNet I/O Mapping Data...

Página 35

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 38 Attribute ID Access rule Name Range Default Explanation for module 1

Página 36

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 39Attribute ID Access rule Name Data type … … … UINT 9 Get/Set Co

Página 37

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 31 Introduction 1. To ensure correct installation and operation of RTU-

Página 38

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 4 Baud rates 125 kbps; 250 kbps; 500 kbps  Electrical specification Vo

Página 39

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 5Default I/O mapping data (DeviceNet → RTU-DNET) I/O mapping data (RTU-

Página 40

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 6 2.3 DeviceNet Connection Port The connector is used on the connection

Página 41

DeviceNet Remote I/O Communication Module RTU-DNET DVP-PLC Application Manual 7OFF When DeviceNet is off, the I/O data in the buffer area will be clea

Comentários a estes Manuais

Sem comentários