Chapter 7 Example Explanation|ScrEdit Software User Manual
7-6 Revision Apr. 30th, 2007, 2007PDD23000002
Fig. 7.7
The Configuration of the HMI control must be set-up to control the drive.
To do this you must set the baud rate and signaling for the HMI and the drive.
The computer must be set-up to download the information to the HMI written in the HMI
programming language.
This set-up is 7, N, 2, 38,400, HMI 0, PLC 1, RS485 interface.
This is done in the Configuration section of the HMI program.
The screen will look like Fig. 7.8.