Delta Electronics LCP-1250 Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 14
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
DELTA ELECTRONICS, INC.
12 Nov., 2006
Rev. 6B
www.deltaww.com
5) Byte 95 contains the low order 8bits of sum of bytes 0-94
6)
State/ Control Bits
Byte Bit Name Description
110 7 Tx Disable State Digital state of the Tx disable input pin
110 6 Soft Tx Disable Read/ Write bit that allow software disable of laser
110 5 Reserved
110 4 Rate Select tate NA
110 3 Soft Rate Select NA
110 2 Tx Fault Digital state of the Tx fault output pin
110 1 LOS Digital state of the LOS output pin.
110 0 Data_Ready_Bar NA
7)
Optional Set of Alarm and Warning
Byte Bit Name Description
112 7 Temp High Alarm Set when internal temperature exceeds high alarm level
112 6 Temp Low Alarm Set when internal temperature is below low alarm level
112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level
112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level
112 3 Tx Bias High Alarm Set when Tx Bias current exceeds high alarm level
112 2 Tx Bias Low Alarm Set when Tx Bias current is below low alarm level
112 1 Tx Power High Alarm Set when Tx output power exceeds high alarm level
112 0 Tx Power Low Alarm Set when Tx output power is below low alarm level
113 7 Rx Power High Alarm Set when received power exceeds high alarm level
113 6 Rx Power Low Alarm Set when received power is below low alarm level
113 5-0 Reserved
116 7 Temp High Warning Set when internal temperature exceeds high warning level
116 6 Temp Low Warning Set when internal temperature is below low warning level
116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level
116 4 Vcc Low Warning Set when internal supply voltage is below low warning level
116 3 Tx Bias High Warning Set when Tx Bias current exceeds high warning level
116 2 Tx Bias Low Warning Set when Tx Bias current is below low warning level
116 1 Tx Power High Warning Set when Tx output power exceeds high warning level
116 0 Tx Power Low Warning Set when Tx output power is below low warning level
117 7 Rx Power High Warning Set when received power exceeds high warning level
117 6 Rx Power Low Warning Set when received power is below low warning level
117 5-0 Reserved
Digital Diagnostic Monitor Accuracy
Parameter Typical Value Note
Transceiver Temperature
± 3
1
Power Supply Voltage ± 3% 2
TX Bias Current ± 10%
TX Optical Power ± 1.5dB
RX Optical Power ± 3dB
Notes:
1) Temperature is measured internal to the transceiver.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14

Comentários a estes Manuais

Sem comentários