Absolute Maximum Ratings
Storage Temperature Ts -40 85 ºC
Supply Voltage V
CC
0 5 V
Recommended Operating Conditions
Case Operating Temperature T
C
-5 70 ºC 1
Supply Voltage V
CC
3.135
3.465
V
Note 1: See order information
Electrical Characteristics
(V
CC
=3.3V ± 5%)
CCT
Transmitter
Transmitter Differential Input Voltage V
DT
0.5 2.4 V 1
Transmitter Disable Input-High V
2 V
+0.3
V
Transmitter Disable Input-Low V
0 0.8 V
Transmitter Fault Pull up Resistor R
4.7 10 kΩ 2
Transmitter Fault Output-High V
2 V
+0.3
V 2
Transmitter Fault Output-Low V
0 0.8 V 2
Receiver
Receiver Differential Output Voltage V
DR
0.35 1 2 V 3
Receiver LOS Load R
4.7 10 kΩ 2
LOS Output Voltage-Low V
0 0.8 V 2
Output Data Rise/Fall Time t
/ t
220 psec 4