Chapter 2 Creating and Editing Screens
_
ScrEdit Software User Manual
Revision Apr. 30th, 2007, 2007PDD23000002 2-101
5. Set the display text of “Set” button element in different languages.
z Double click the “Simplified Chinese” and enter “ ” in Simplified Chinese”
z Double click the Traditional Chinese tab and enter “
” in Traditional Chinese.
z Double click the English tab and enter “
Alarm
” in English.
6. In property setting of “Increment” button element, please set the write address as the internal memory
$207.
7. Then, set the setting value of “Before Execute Macro”. The user can enter the Macro command as
$207=$207%3.