Delta Electronics AC Drive VFD-F Series Especificações Página 112

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 190
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 111
5
VFD-F Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-79
03-03 N/A N/A N/A 04
Motor 4 runs
by AC drive.
N/A 04
Motor 2 runs
by
commercial
power.
04
Motor 2 runs
by
commercial
power.
04
Motor 2 runs
by
commercial
power.
03-04 N/A N/A N/A N/A N/A N/A 05
Motor 3 runs
by AC drive.
05
Motor 3 runs
by AC drive.
03-05 N/A N/A N/A N/A N/A N/A 06
Motor 3 runs
by
commercial
power.
06
Motor 3 runs
by
commercial
power.
03-06 N/A N/A N/A N/A N/A N/A N/A 07
Motor 4 runs
by AC drive.
03-07 N/A N/A N/A N/A N/A N/A N/A 08
Motor 4 runs
by
commercial
power.
11 - 03
Time Circulation Time Setting
Factory Setting: 00
Settings 00~65500 Min Unit: 1 Min
This parameter is to set running time of each motor (including acceleration time) when multiple
motors are in time circulation mode (11-01=1). If this parameter is set to 00, time setting is disabled
and run with a motor.
If multi-function input terminals (04-00 to 04-07) are set to 27 to 31, the corresponding output
terminals will skip and not activate. The following diagram is the action schedule of time circulation
when motor 3 is disabled.
The motor, which is running with AC drive doesn’t accept any disable command of motor.
When switching time circulation, AC drive won’t provide this selection when running motor is coast
to stop.
Output
Frequency
03-00 01
Run
Motor 3 disable
03-01 02
03-02 03
03-03 04
11-04
11-03
11-01 01
11-02 04
04-00 29
Vista de página 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 189 190

Comentários a estes Manuais

Sem comentários