11 - 03
Time Circulation Time Setting
Factory Setting: 00
Settings 00~65500 Min Unit: 1 Min
This parameter is to set running time of each motor (including acceleration time) when multiple
motors are in time circulation mode (11-01=1). If this parameter is set to 00, time setting is disabled
and run with a motor.
If multi-function input terminals (04-00 to 04-07) are set to 27 to 31, the corresponding output
terminals will skip and not activate. The following diagram is the action schedule of time circulation
when motor 3 is disabled.
The motor, which is running with AC drive doesn’t accept any disable command of motor.
When switching time circulation, AC drive won’t provide this selection when running motor is coast
to stop.
Output
Frequency
03-00 01
Run
Motor 3 disable
03-01 02
03-02 03
03-03 04
11-04
11-03
11-01 01
11-02 04
04-00 29