03 - Comparison of Terminals between CP2000 & VFD-F
3-2
VFD-F VFD-CP2000
Terminals
Terminal Function Factory Setting (NPN mode) Terminals
Terminal Function Factory Setting (NPN mode)
RA1
Multi-function Relay1 output
(N.O.) a
RA1
Multi-function relay output 1
(N.O.) a
RB1
Multi-function Relay1 output
(N.C.) b
RB1
Multi-function relay output 1
(N.C.) b
RC1 Multi-function Relay1 common RC1
Multi-function relay common
(Relay)
RA2
Multi-function Relay2 output
(N.O.) a
RA2
Multi-function relay output 2
(N.O.) a
RB2
Multi-function Relay2 output
(N.C.) b
RC2 Multi-function Relay2 common
1.5A(N.O.)/1A(N.C.) 240VAC;
1.5A(N.O.)/1A(N.C.) 24VDC;
Refer to Pr.03-00 to Pr.03-01
RC2
Multi-function relay common
(Relay)
RA3
Multi-function relay output 3
(N.O.) a
RC3
Multi-function relay common
(Relay)
Resistive Load:
5A(N.O.)/3A(N.C.) 250VAC
5A(N.O.)/3A(N.C.) 30VDC;
Inductive Load (COS 0.4):
2.0A(N.O.)/1.2A(N.C.)
250VAC;
2.0A(N.O.)/1.2A(N.C.)
30VDC;
It is to output each monitoring
signal, such as drive is in
operation, frequency attained or
overload indication.
+10V Potentiometer power source +10V 20mA +10V Potentiometer power supply
Analog frequency setting:
+10Vdc 20mA
Analog voltage input
AVI Analog voltage Input
0 to +10V correspond to Max.
operation frequency
AVI1
Impedance: 20kΩ;
Range: 0~ 20mA/0~10V =0~
Max. Output Frequency
(Pr.01-00);
AVI switch, factory setting is
0~10V;
Analog current input
ACI1/2 Analog current Input
4 to 20mA correspond to Max.
operation frequency
ACI
Impedance: 250Ω;
Range: 0 ~ 20mA/0~10V=0~
Max. Output Frequency
(Pr.01-00);
ACI Switch, factory setting is
0~20mA;