Chapter 13 Recipe Access Example
Revision March, 2014 13-11
When eServer performs reading, due to enable the auto refresh on startup, eServer will
execute import recipe to destination path. But if disable the auto refresh on startup,
eServer will wait for 5 second then the eServer execute import recipe to destination path.
After import recipe, user could examine and check if the saved file name is saved in the
destination path or not. Please refer to the figure such as
.
On the other hand, if incorrect or invalid password is entered, the following error
message dialog box will appear to alert the users.
Import - Variance
Setting
a. Select Variance.
:
b. Check the check box to use 16-bit recipe as the example.
c. Set the File Name (file name of the imported file) to be the same as the register
address of HMI. (In this case $100 character input element is used)
d. Set File Name Length (number of the imported characters). (In this case the File Name
Length is set to 4. This is because the name of the imported file is Tina.csv. The
system will refer to Tinathese four characters and convert the imported file to
Tina.rcp and then save it to the destination path.)
e. Select Format as RCP.
f. Set Destination Path (destination location) where the imported file is located.
g. Enable Auto Refresh on Startup.