1-4 Fabric Watch User’s Guide
Introducing Fabric Watch
1
Figure 1-2 shows a typical example of an error counter with a rising/falling threshold.
Figure 1-2 Example of Rising/Falling Threshold: Error Rate
Change Monitor Threshold
A change monitor threshold generates events whenever a counter value changes, regardless of the
type of change. This type of threshold is usually used to indicate state changes, such as zoning
changes.
Note: The change monitor counter value displayed is the cumulative count (historical count) and
not the delta value from the previous triggered value.