DS_DNS10SIP06_03092009
13
THERMAL CURVES
Figure 30: Temperature measurement location
he allowed maximum hot spot temperature is defined at 120
℃
DNS10S0A0R06(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 12V, Vo = 5.0V (Either Orientation)
0
1
2
3
4
5
6
7
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (℃)
Output Current(A)
Natural
Convection
100LFM
200LFM
300LFM
400LFM
500LFM
600LFM
Figure 31:DNS0A0R06(Standard) Output current vs. ambient
temperature and air velocity@ Vin=12V, Vout=5.0V (Either
Orientation)
DNS10S0A0R06(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 12V, Vo = 1.8V (Either Orientation)
0
1
2
3
4
5
6
7
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (℃)
Output Current(A)
Natural
Convection
100LFM
200LFM
300LFM
500LFM
400LFM
Figure 32: DNS0A0R06(Standard)Output current vs. ambient
temperature and air velocity@ Vin=12V, Vout=1.8V (Either
Orientation)
DNS10S0A0R06(Standard) Output Current vs. Ambient Temperature and Air Velocity
@ Vin = 12V, Vo = 0.75V (Either Orientation)
0
1
2
3
4
5
6
7
30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (
℃
)
Output Current(A)
Natural
Convection
100LFM
200LFM
300LFM
400LFM
500LFM
Figure 33: DNS0A0R06(Standard) Output current vs. ambient
temperature and air velocity@ Vin=12V, Vout=0.75V (Either
Orientation)
Comentários a estes Manuais