Delta-electronics ASDA-B Series Manual do Utilizador Página 207

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 206
Chapter 7 Servo Parameters|ASDA-B Series
7-54 Revision January, 2009
ASD-PU-01A ASD-PU-01B
Motor Startup Operation Settings:
0: No operation. The motor does not run.
1: Motor startup operation. The motor starts to run.
Responsiveness Selection Settings:
0: Auto-select the appropriate responsiveness according to the measured load inertia value
1: Select the responsiveness set by parameter P2-31
P2 - 48
CCLR Pulse Deviation Clear Mode Communication Addr.: 0230H
Default: 0 Related Section:
Applicable Control Mode: P DI CCLR(04) in Table 7.A
Unit: N/A
Range: 0 ~ 1
Settings:
When the servo drive is set to CCLR mode, the pulse deviation clear function is enabled.
0: When the input terminal is rising-edge triggered, the position accumulated pulse number will
be cleared.
CCLR
1: After CCLR is activated (ON), the position accumulated pulse number will be cleared
continuously.
The position accumulated pulse number
will be cleared continuously after CCLR
is activated (ON).
CCLR
Vista de página 206
1 2 ... 202 203 204 205 206 207 208 209 210 211 212 ... 320 321

Comentários a estes Manuais

Sem comentários