Delta Electronics AC Servo Drive ASDA-AB Manual do Utilizador Página 105

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 104
Chapter 6 Control Modes of Operation ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
6-8
TSL/2
TDEC
TSL/2
TSL/2
TDEC
TSL/2
P-curve characteristics and Time relationship (Deceleration)
Time (ms)
Time (ms)
Position
Speed
Rated speed
Tor qu e
Relevant parameters:
P1 - 34 TACC
Acceleration Time Communication Addr.: 0122H
Default: 200 Applicable Control Mode: P/S
Range: 1~20000
Unit: msec
P1 - 35 TDEC
Deceleration Time Communication Addr.: 0123H
Default: 200 Applicable Control Mode: Pr/S
Range: 1~20000
Unit: msec
P1 - 36 TSL
Accel /Decel S-curve Communication Addr.: 0124H
Default: 0 Applicable Control Mode: P/S
Range: 0~10000 (0: disabled)
Unit: msec
Note: If the setting value of parameter P1-36 is set to 0, it indicates Accel / Decel S-curve function is
disabled and the command is just By-Pass.