Delta Electronics AC Servo Drive ASDA-AB Manual do Utilizador Página 128

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 127
ASDA-A User Manual Chapter 6 Control Modes of Operation
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED 4th Edition 2005/11/30, HE03
6-31
6-4-3 Smoothing Strategy of Torque Control Mode
P1 - 07 TFLT
Smooth Constant of Analog Torque Command
(Low-pass smooth filter)
Communication Addr.: 0107H
Default: 0 Applicable Control Mode: T
Range: 0~100 (0: Disabled)
Unit: msec
Note: If the setting value of parameter P1-07 is set to 0, it indicates the function of this parameter is
disabled and the command is just By-Pass.
TFLT
Ta r ge t S p ee d
Vista de página 127