ASDA-A User Manual Chapter 7 Parameters
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED 4th Edition 2005/11/30, HE03
7-7
Group 3: P3-xx
Communication Parameters
Control
ModeParameter Name Function Default Unit
P S T
P3-00 ADR Communication Address 1 --- O O O
P3-01 BRT Transmission Speed 1 bps O O O
P3-02 PTL Communication Protocol 0 --- O O O
P3-03 FLT Transmission Fault Treatment 0 --- O O O
P3-04 CWD Communication Time Out Detection 0 sec O O O
P3-05 CMM Communication Selection 0 --- O O O
P3-06Ϯ SDI Digital Input Contact Control 0 --- O O O
P3-07 CDT Communication Response Delay Time 0 0.5msec OOO