Delta Electronics Ethernet Extension Module DOP Especificações Página 129

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 128
Train ing Kit O peratio n Manua l
5-2
5.1 ROL/RORNeon Lamp Design
Y0
Y1 Y2
Y3
Y4
Y5 Y6
Y7
Y10 Y11 Y12
Y13
Y14
Y15
Y16
Y17
X0
X1
X2
1. Control purpose
After the Right Rotation button is pressed, the 16 neon lamps will be turned on for 200
milliseonds in the order Y0~Y7 and Y10~Y17.
After the Left Rotation button is pressed, the 16 neon lamps will be turned on for 200
milliseonds in the order Y17~Y10 and Y7~Y0.
Users do not have to press the Reset button when switching between the Right Rotation
button and the Left Rotation button.
After the Reset button is pressed, all the neon lamps will be turned off.
2. Devices
Device Function
X0
Right Rotation button
X0=ON when the button is pressed.
X1
Left Rotation button
X1=ON when the button is pressed.
X2
Reset button
X2=ON when the button is pressed.
T0/T1
200 ms timer
Time base: 100 ms.
Y0~Y17 16 neon lamps
Vista de página 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 174 175

Comentários a estes Manuais

Sem comentários