Appendix A Com m unic ation Sett i n g
A-5
(2) Connection type
Users can select a connection type in the
Type
drop-down list box. The connection types
supported by COMMGR are as follows.
RS232
A computer communicates with a PLC through a communication port on the computer.
USB (Virtual COM)
A computer can connect to a PLC equipped with a USB port through a USB cable. However,
users have to make sure that a USB driver is installed on a computer before the computer
connects to a PLC equipped with a USB port. Please refer to appendix A for more information
about installing a USB driver.
Ethernet
A computer communicates with a PLC through an Ethernet port on the computer.
DirectLink (USB) & DirectLink (Ethernet)
They are the connection functions provided by Delta human-machine interfaces (HMI). If a
PLC connects to a HMI normally, a computer can connect to the HMI through a USB cable or
Ethernet, and connect to the PLC indirectly. Please refer to manuals for Delta
human-machine interfaces for more information about setting a connection.
DVP Simulator & AH Simulator
This type of driver functions as a virtual channel connecting a simulator. If users specify this
type of driver in ISPSoft, COMMGR will transmit data between ISPSoft and a simulator once
related connection operation is performed. It is as if COMMGR connected to a real PLC.
(This mode is a framework adopted by ISPSoft version 2.00 and above.)
(3) Communication parameters
Communication parameters are set according to a connection type selected. Different
connection types have different communication parameters. The setting of parameters for the
different connection types is described in the following sections.